Karandikar Laboratories Pvt. Ltd. (Inspection & Training Division)
Address Gat No. 142, Boisar Chilhar Road, Opp. Union Park, At Betegaon, Boisar (E), Tal. Palghar – 401501, India
Contact Person Mr. Ajit Karandikar
Designation  
Tel 022 - 2847 1395 / 97 / 98
Fax 0120-2530751/2529801/891
Email ID ajitk@karandikarlab.com
Website http://www.karandikarlab.com
Accreditation Cert. No.. IB 036
Valid From 20 February 2017
Valid Upto 19 Aug 2024
Accreditation Standard ISO/IEC 17020:2012
Type of Inspection Body Type A
 
Scopes of Accreditation

Field of Inspection

Type and Range of Inspection

Standards / Regulations / Methods / Procedures

Number identification with year of publication

Title

IAF Scope 19
Electrical Equipments

Inspection / Verification of All types of Electrical Equipment used in Hazardous areas

 

Inspection of Manufacturing Process & final Inspection of Electrical Products for use in Hazardous areas

 

ISO/IEC, ISO/EN 80079-34: 2011 Edition 1.0

 

Explosive Atmospheres: Application of Quality Systems for Equipment Manufacture. Customer specification / QAP

Inspection / Verification of All types of Electrical Installations in Hazardous areas

Inspection of Area Classification of Hazardous AreasInstallations

IEC 60079-10-1 && EN 60079-10-1

Explosive Atmospheres: Part 10-1: Classification of Areas – Explosive Gas Atmospheres

 

 

IEC 60069-10-2 & EN 60079-10-2

Explosive Atmospheres: Part 10-2: Classification of Areas – Explosive Dust Atmospheres

 

 

IS 5572,

Classification of Hazardous Areas (Other than Mines) having Flammable Gases and Vapoursfor Electrical Installations

 

 

IP 15

The area classification code for petroleum installation

 

 

API RP 500

Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Division I and Division 2,

 

 

API RP 505

Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2

 

Inspection of: Design of Electrical Installations in Hazardous areas

IEC 60079-14 Edition 5.0 2013; EN 60079-14: 2013

Explosive Atmospheres: Electrical Installations Design, Selection & Erection

 

2) Selection of Electrical Equipment in Installations Hazardous areas

IS 16724:2018

Guide for Selection and Installation of Electrical Equipment in Hazardous Areas (other than Mines)

 

3) Erection of Electrical Installations in Hazardous areas

ATEX Directives No. 2014/34/EU, 99/92/EC

Directive 2014/34/EU of the European Parliament and of the Council of 26th February 2014 on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres (recast)

 

4) Inspection of Electrical Installations in Hazardous areas
* Visual Inspection
* Close Inspection
* Detailed Inspection

IS/IEC 60079-17: 2007
IEC 60079-17 Edition 5.0
EN 60079-17

Explosive Atmospheres – Part 17: Electrical Installations Inspection and Maintenance

 

 

AS/NZS 2290.1-2014

Electrical equipment for Coal Mines – Introduction, Inspection & Maintenance (Australia and New Zealand)

 

 

IS 4051

Code for Practice for Installation and maintenance of Electrical Equipment in Mines.

 

 

ATEX Directives No. 2014/34/EU, 99/92/EC

Directive 2014/34/EU of the European Parliament and of the Council of 26th February 2014 on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres (recast)

 

Inspection of Electrical Equipment during and after Installations in Hazardous Areas(restricted to hazardous area only)

GSR 612(E) 27 Aug 2008as amended from time to time

Ministry of Environment & Forest notification

IAF Scope 26
Gas Supply

 

Requirements as per PNGRB Regulations 2016-Infra T4S/LNG/05 (For electrical equipment safety integrity in hazardous area only

  PNGRB Technical Standards and Specifications including Safety Standards for LNG Regulation 2008

 
The following offices of   Karandikar Laboratories Pvt. Ltd. (Inspection & Training Division)are included under accreditation

S.No

Location

Address

Key activities performed


01


Main office


Gat No. 142, Boisar Chilhar Road, Opp. Union Park, At Betegaon, Boisar (E), Tal. Palghar - 401501, India


Top management functions, quality management system functions, administration & accounts, other key activities as applicable to main office.

Inspection contract review, Inspection planning & execution, Inspection personnel authorization & assignment, Issue of inspection reports / certificates.