NABCB Accredited Inspection Bodies
RINA India Pvt. Ltd.
Address B-607 / 608, Everest Chambers, Marol Naka, Andheri-Kurla Road, Andheri (E), Mumbai - 400059, India
Contact Person Mr. Naveen Kumar
Designation Head - Transport & Infrastructure BU
Tel +91 96 507 90586 / 93 106 72003
Mob +91 96 507 90586 / 93 106 72003
Fax 022 - 2852 5139
Email ID naveen.kumar@rina.org, kavita.negi@rina.org
Accreditation Cert. No.. IB 028
Valid From 21 May 2015
Valid Upto 20 May 2026
Accreditation Standard ISO/IEC 17020:2012
Type of Inspection Body Type A
 
Scopes of Accreditation

Field of Inspection

Type and Range of Inspection

Standards / Regulations / Methods / Procedures

Number identification with year of publication

Title

IAF Scope 17a

Basic Metal Products

Pipes, Tubes, Pipe Fittings, Plates, Structural items, Fasteners, Coils

Stage wise / finished product inspection

ASME Sec II Part A&B - 2013

BPVC SECTION II - Materials - Part A - Ferrous Material specifications Part B - Non Ferrous Material specifications

 

ASME Sec. V - 2013

BPVC Section V - Non destructive Examination

 

API 5L - 2012

Specification for Line Pipe

 

IS 3589 - 2001

Steel pipes for water and sewage (168.3 to 2540 mm outside diameter) - specification

 

IS 1239 - 2011

Mild Steel Pipes for water, Gas,Steam, and Air Line Steel Tubes, Tubulars, and other wrought steel fittings

 

IS 2062 - 2011

Hot Rolled Medium and High tensile structural steel

 

IS 1079 - 2009

Hot rolled carbon steel sheet and strip

 

IS 1599 - 2012

Metallic Materials - Bend Test

 

NACE MR0175/ISO 15156� - 2001

Materials for use in H2S containing environment in Oil and Gas Production

IAF Scope 17b

Fabricated Metal Products

Pressure vessels, Tanks, Pressure parts & accessories, Steel pipe fabrication

Stage wise / finished product inspection

ASME Sec VIII Div 1 :- 2013

PD 442 - BPV code, Section VIII Division 1:- Design and Fabrication of Pressure Vessels

 

ASME Sec. IX - 2013

BPV Code, Section IX: Welding, Brazing and Fusing Qualifications

 

ASME Sec V- 2013

BPV Code, Section V: Non destructive Examination

 

ASME B31.3 - 2012

Process piping

 

API 1104 -- 2013

Standard for welding pipelines and related facilities

IAF Scope 18

Machinery and Equipment

Pumps � Horizontal / vertical , centrifugal Reciprocating

Stage wise / finished product inspection

API 610 - Jan 2003

Centrifugal Pumps for Petroleum , Petrochemical and natural Gas Industries

 

API 685 - October 2000

Seamless Centrifugal Pumps for Petroleum, Heavy duty chemical and Gas Industry services

 

IS 6595 (Part I) - 2002

Horizontal Centrifugal Pumps for clear, cold water� (agricultural and rural water supply purposes)

 

 

IS 6595 (Part 2) - 2002

Horizontal Centrifugal Pumps for clear, cold water� ( other than agricultural and rural water supply purposes)

 

 

IS 9137 � 1978 (fifth reprint June 1997)

Code for acceptance test for centrifugal, mixed flow and axial pumps � class C

Valves - Globe, Gate, Check

 

IS 778 - 1984

Specification for Copper alloy, Gate, Globe and check valves for water works purposes

 

 

API 6A - 1999

Specification for Well head and Christmas Tree Equipment

 

 

API 6D - 2002

Pipeline Transportation systems � Pipeline valves

 

 

API 527 - 1991

Seat tightness of Pressure relief valves

 

 

API 594� - 1997

Check valves : wafer , Wafer � Lug and double flanged type

 

 

API 598� - 2009

Valve inspection and testing

 

 

API 600 - 2001

Bolted Bonnet Steel Gate valves for Petroleum and Natural gas Industries

 

 

API 603 - 2001

Corrosion resistant, Bolted Bonnet Gate valves- Flanged and Butt � welding ends

 

 

API 607 - 2005

Fire Test for Soft seated Quarter turn Valves

 

 

API 608 - 2002

Metal Ball Valves- Flanged, threaded and welding ends

 

 

API 609 - 2004

Butterfly Valves : - Double Flanged, Lug and wafer type

IAF Scope 19
Electrical products

 

 

 

Insulated Wires & Cables

Stage wise / finished product inspection 

IEC 60502 - 200 / AMD1 2009
IEC 60502 - 2 2014

Power cable with extruded insulation and their
accessories for rated voltages from 1 kV (Um-1.2 kV) upto 30 kV (Um-36 kV).

 

 

IEC 60227- 1 : 2007


IEC 60227- 2 : 1997/AMD1 2003

IS : 7098

Polyvinyl chloride insulated cables of rated voltages
upto and including 450/750V

General Requirement


Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V.

 

 


Part-1
1988/2015,

Part-2
2011/2016,

Part-3
1993/2014


Test Methods


Crosslinked polyethylene insulated PVC sheathed cable.


Part-1 for working voltage upto and including 1100V.

Crosslinked polyethylene insulated thermoplastic sheathed cable.

Part-2 for working voltage from 3.3 kV upto and including 33kV

Crosslinked polyethylene insulated thermoplastic sheathed cable.

Part-3 for working voltage from 66 kV upto and including 220 kV

 

 

IS:1554

PVC insulated (Heavy Duty) electric cables.

 

 

Part-1, 2

Part-1 for working voltage upto &

 

 

1988/2015,

including 1100 V

 

 

Part-2 for working voltage from 3.3kV upto & including 11 kV.

Electricity Distribution and control apparatus

 

IEC-60947-1 2007 / Amd 1 2010 and Amd 2 2014

Low voltage switchgear and control gear Part1 : General Rules

 

 

IEC-60947-2 Ed 5.0 2016

Part2 : Circuit Breakers

 

IEC-60947-3 2008 /AMD1 2012 /AMD2 2015

Part3 : Switches, disconnectors andfuse combination units

 

 

IEC-60947-42009 / AMD1

Part 4: - Contactors and motorstarters - Electro mechanical

 

 

IEC-60947-5 -1: 2016

Part 5: - Control circuit devices andswitching elements - Electromechanical control circuitdevices

 

 

IEC-62271-1- 2017

High voltage switchgear and control gear Part 1: Common spec for alternating current switchgear and control gear

 

 

IEC 60076-2000

Power Transformers

 

 

IEC-62271- 100-2008 / AMD2 2017

Part 100: Alternating current circuit breakers.

 

 

IEC-62271- 200-2011

Part 200: AC metal enclosed switchgear and control gear for rated voltages above 1kV and upto & including 52 kV.

 

IEC-60439-2006 Part 1 to 5

Low voltage switchgears andcontrol gears assemblies

 

 

IS:13947-2004

Low voltage switchgear and control gear

 

 

Part-5 2004/2014

Part-5 Control circuit devices & switching elements. Sec.2 : Proximity switches.

 

 

IS:8623 Part-1, 2, 3 1993/2013

Low voltage switchgear and control gear assemblies. Part-1 Requirements for type tested& partially type tested assemblies. Part-2 Particular requirements for Busbar trunking systems (Busway) Part-3 Particular requirements for Equipment where unskilled persons have access for their use.

 

Lighting equipments, Electric lamps

 


IEC 60079-0
2011


Electrical apparatus for explosive gas atmosphere - Part-0 General requirements.

Electric Motors, Generators and Transformers  

 

IEC-60598- 2014/2015 Part 1,2-5

Luminaires - Part 1:General requirements & tests Part 2-5: Particular requirements - Floodlights

 

 

IS 325 - 1996/2012

Three Phase induction motor specification

 

 

IEC 60034-12017,

Rotating electrical machines

 

 

IS- 4029- 2010/2016

Guide for testing of three phase induction motors

 

 

IEC 60076-1: 2011,

Power Transformers.

 

IS 2026 Part-1 2011/2016

Power Transformers Part-1 General

 

 

Part-2 2010/2015,

Part-2 Temperature rise.

 

 

Part-3 2009/2014,

Part-3Insulationlevels,dielectrictests &externalclearancesinair.

 

 

Part-4 1977/2016, Part-5 2011/2016,

Part-4Terminalmarking,tappings& connections. Part-5 Ability to withstand short circuit.

 

 

Part-6 2017,

Part-6 Reactors.

 

 

Part-7 2009/2014,

Part-7Loadingguideforoilimmersed powertransformers.

 

 

Part-8 2009 / 2014,

Part-8 Application guide

 

 

Part-10 2009 / 2014

Part-10Determinationofsoundlevels.

 

 

Part- 12 2018

Part-12 Power Transformers Part 12 Loading Guide for Dry-type Power Transformers

Instrument & Appliances for Measurement, Testing & Navigating 

 

Part- 14 2018

Part-14 Power Transformers Part 14Liquid-Immersed PowerTransformers Using High-Temperature Insulation Materials

 

 

Part- 15 2018

Part 15 Power Transformers Part 15Gas-Filled Power Transformers

 

 

Part- 16 2018

Part 16 Power Transformers Part 16Transformers for Wind TurbineApplications

 

 

Part- 18 2018

Part 18 Power Transformers Part 18Measurement of FrequencyResponse

 

 

IS:11171- 1985/2016

Dry type Power Transformers.

 

 

IS:1180

Outdoor type oil immersed distributiontransformersupto& including 2500 kVA, 33 kV specifications

 

 

Part-1 2008/2014, IEC 61511-

Part-1 Mineral oil immersed. Functional Safety � Safety

 

 

2016 Part 1 to 3

Instrumented Systems for the process industry sector.

 

 

IEC 61508- 2010

Functional Safety of Electrical/Electronic/Programmable electronic Safety related Systems

 

 

IEC 61158- 2014 Part 1 to 6

Digital data communications for measurement and control-Fieldbus for use in industrial control systems.

 

 

IEC 60534-2015 Part 1 to 8

Industrial Process Control Valves

Process Control Equipment/System 

 

IS 12754- 1989/2015 Part 1 to4

Process Measurement Control Functions & Instrumentation

 

 

IS 13122- 1992/2016 Part 1 to2

Transmitters for use in Industrial Process control system

 

 

IS 7722- 1975/2013

Analogue Pneumatic Signals for Process Control System

 

 

IS 7728- 1984/2015

Analogue DC current Signals for Process Control System

 

 

IS 8493- 1977/2015

Analogue DC voltageSignals for Process Control System

 

 

IS 14570- 2012/2017

Electrical Measuring Transducers for converting ac electrical quantities to Analogue or Digital signals

 

 

IEC 61131-2018 Part 1 to 9

Programmable Controllers

 

 

IEC 62264-2016 Part 1 to 6

Enterprise Control System Integration

IAF Scope 25

Electricity Supply
Scope 25 under suspension w.e.f. 22 Mar 2022


Generation of Electricity �



A.C. Generator

Power Transformer

 Installation, Erection and Commissioning Inspection

 IEEE 1248



Edition 5 of
IEC 60079-14-
2013


IEC 60034-1 2017,
IS 10028 : Part 1 to 3- 1985
Reaffirmed- 2016

IEC 60076-1: 2011, IS 2026

Guide for the Commissioning of Electrical Systems in Hydroelectric Power Plants.


Electrical installations design, selection and erection  



Rotating electrical machines Code of Practice for
Selection,Installation and
Maintenance of Transformers - Part 1 to 3 : Selection,Installation & Maintenance

Power Transformers

Transmission of Electricity �
1. HighVoltage Cables.

2. HighVoltage Switchgear &Controlgear  

 

IS 1255: 1983- Reaffirmed 2016



IS 10118 : Part1 to4-1982- Reaffirmed 2016

Code of practice for installationand maintenance of power cablesupto and including 33 kV rating



Code of Practice for Selection,Installation and Maintenance
of Switchgear and Controlgear - Part Ito IV: General,

Selection,Installation & Maintenance

Distribution of Electricity �

1. Distribution Transformer,  

 

IS 10028 : Part 1 to 3- 1985 Reaffirmed- 2016

Code of Practice for Selection,Installation
and Maintenance
ofTransformers - Part 1 to
3 : Selection,
Installation & Maintenance

 

 

IS 1255: 1983- Reaffirmed 2016

Code of practice for installationandmaintenanceofpowercablesupto and including 33 kVrating


 

 

IEC 60364-5- 52-2009

Low-voltage electrical installations - Selection and erection of electrical equipment - Wiring systems

2. Low Voltage Cables.  

 

IS 10118 : Part1to 4-1982- Reaffirmed 2016

Code of Practice for Selection,Installation and Maintenance ofSwitchgear and Controlgear - Part Ito IV: General, Selection,Installation & Maintenance.

3. Low Voltage Switchgear &Controlgear.  

 

IEC 60364-5- 53-2015

Low-voltage electrical installations - Selection and erection of electrical equipment - Isolation, switching and control

4. Lighting  

 

IEC 60364-7- 714

Low-voltage electrical installations - Requirements for special installations or locations - External lighting installations

5. Solar PV Powersupply systems  

 

IEC 60364-7- 715

Low-voltage electrical installations - Requirements for special installations or locations - Extra-low - voltage lighting installations


 

 

IEC 60364-7- 712

Low-voltage electrical installations - Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems

6. Shunt Power Capacitors  

 

IS 13340 : PART 1: 2012- Reaffirmed 2017

Shunt Power Capacitors of the Self-Healing Type for ac Systems havinga Rated Voltage up to andIncluding 1000 V Part 1 General -
Performance, Testing and Rating -
Safety Requirements -- Guide forInstallation and Operation

7. PLCPanel  

 

IS 13241 : Part1: 1991- Reaffirmed 2014

Code of practice for installationand maintenance of indoor PLCequipment: Part 1 PLC terminals

8. Electronic Transmitters  

 

IS 13122 : Part2: 1991- Reaffirmed 2016

Transmitters for use in industrial process control systems: Part 2 Guidance for installation, inspection and routine testing

IAF Scope 26
Gas Supply

Gas Supply �NGPL with item 26-A (i)




Gas Supply �CGD with item 26-B (i)

Pipelines for production and cross country / city distribution of gaseous fuels


 Stage wise







 Stage wise


 PNGRB�s GSR 808(E) dated 11.11.2009 along with latest amendments, national/ international standards mentioned therein and relevant statutes


 PNGRB�s GSR 612(E) dated 27.08.2008 along with latest amendments, national/ international standards mentioned therein and relevant statutes


 PNGRB�s �Technical Standards and Specifications including Safety Standards for Natural Gas Pipelines� Regulations, 2009






 Petroleum and Natural Gas Regulatory Board ( Technical standards and specifications including safety standards for City or Local Natural Gas Distribution Network)

IAF Scope 27
Water Supply
Scope 27 under suspension w.e.f. 22 Mar 2022

 Stage wise / finished product inspection

 S 1172 : 1993

 Basic requirement for water supply

Water Supply

 

 IS 2065 - 1983

 Code of practice for water supply in buildings

Collection, purification and distribution systems

 

 IS 2064 - 1993

 Code of practice for selection, installation and maintenance of sanitary appliances

 

 IS 456 : 2000

 Plain and reinforced concrete � code of practice , MORTH

 

 IS 5329 : 1983

 specification and IRC specification

 

 IS 783 : 1985

 Code of practice for sanitary pipe work above ground for buildings

 

 IS 10221 : 2008

 Code of practice for laying of concrete pipes

 

 IS 3114 : 1994

 Coating and wrapping of underground mild steel pipeline � code of practice

 

 IS 7634 - 2 : 2012

 Code of practice for laying of cast iron pipes

 

 IS 7634 - 2: 2012 Part2

 Plastic Pipe selection, handling , storage and Installation for Potable water supplies

 

 IS 12288 : 1987

 Laying and jointing of Polyethylene ( PE ) pipes Code of practice for use and laying of Ductile iron pipes

IAF Scope 28

Construction


Building � construction
Site preparation
Completion and installation

 Stage � wise / Final Inspection

Indian Construction code
Applicable IS Standards
International standards
Internal Quality control Procedures





IS 456 � 2000

IS 10262 - 2009

IS 516 - 2004

Project Specification
Concreting,
Concrete mix
Strength of concrete
Brickwork
Batching plant
RMC,
Soil testing
Excavation � safety Code

Plain and reinforced concrete � code of practice , MORTH

Guidelines for concrete mix designproportioning.

Method of test for strength of concrete


Roads � Bituminous and concrete

concrete


IS 1077 - 1992


IS 4925 - 2004

IS 4926 � 2003

IS 2720 - 2002

IS 3764 - 1992

IS 2911 - 2010

IS 1742 - 2002

IS 1742 � 2002

Morth � 2001 IRC �


S-3370 part- 1& 2 (liquid retaining structure


Specification for common
burnt clay building bricks

Concrete batching and mixing plan

Code of practice ready-mixed concrete

Method of test of soil

Code of safety for excavation work

Design and construction of pile foundation

Code of practice for building drainage

Code of practice for building drainage

Ministry of Road Transport and Highways ( Indian Roads Congress)

Design, Specification & Testing of Rigid and Flexible pavement.
(liquid retaining structure)

 
The following offices of  RINA India Pvt. Ltd. is/are included under accreditation

S.No

Location

Address

Key activities performed


01


Main office


B-607 / 608, Everest Chambers, Marol Naka, Andheri-Kurla Road, Andheri (E), Mumbai � 400059, India


Top management functions, quality management system functions, administration & accounts, other key activities as applicable to main office.

Inspection contract review, Inspection planning & execution, Inspection personnel authorization & assignment, Issue of inspection reports / certificates.


 Print 
 Close 
Close Search Window