Sunkonnect Advisory Services Private Limited
Address 301-304, JMD Empire, Sector 62, Gurugram – 122102, Haryana, India
Contact Person Mr. Raghavendra Lawaniya
Designation Director
Tel + 91-9205111033
Fax
Email ID raghavendra.lawaniya@sunkonnect.co
Website  http://www.sunkonnect.co/
Accreditation Cert. No.. IB 152
Valid From 04 June 2025
Valid Upto 03 June 2028
Accreditation Standard ISO/IEC 17020:2012
Type of Inspection Body Type A
Scopes of Accreditation
         

IAF Scope /

Field of Inspection and Specific Item(s)

Stage and Range of Inspection(s)

Inspection Requirement(s)

Standards / Regulations / Methods / Procedures

Number identification with year of publication

Title

IAF Scope 17 Basic Metals and Fabricated Metal Products

     
           

Threaded Steel Fasteners (Bolts, Screws, Studs & Nuts)

Stagewise / Final Inspection IS 1363: Part 1: 2023 IS 1363: Part 2: 2018 IS 1363: Part 3: 2018 IS 1364: Part 1: 2023 IS 1364: Part 2: 2023 IS 1364: Part 3: 2018 IS 1367: Part 1: 2014 IS 1367: Part 2: 2002 IS 1367: Part 3: 2017 IS 1367: Part 5: 2018 IS 1367: Part 6: 2025 IS 1367: Part 7: 1980 IS 1367: Part 8: 2020 IS 1367: Part 9: [Sec 1 & Sec 2]: 1993 IS 1367: Part 10: 2002 IS 1367: Part 11: 2024 IS 1367: Part 12: 1981 (Reaffirmed 2018) IS 1367: Part 13: 2020  Standard Specification for Steel, Stainless-Steel, Alloy-Steel and Stainless-Steel Fasteners  

IS 1367: Part 14: [Sec 1 & Sec 2: 2023] [Sec 3: 2018], [Sec 4: 2023] IS 1367: Part 16: 2002 (Reaffirmed 2023) IS 1367: Part 17: 2023 IS 1367: Part 18: 1996 (Reaffirmed 2021) IS 1367: Part 19: 1997 IS 1367: Part 20: 1996 (Reaffirmed 2021)

 
 
Module Mounting Structures / Transmission Line Structures Stagewise / Final Inspection

IS 2062: 2011

IS 15961: 2012
Hot Rolled Medium and High Tensile Structural Steel Hot Dip Aluminium – Zinc Alloy Metallic Coated Steel, Strip and Sheet (Plain)  

IAF Scope 19 Electrical and Optical Equipment

 

Power Transformer

Stagewise / Final Inspection IS 2026 (Part-1):2011 IS 2026 (Part 2): 2010 Reaffirmed 2015 IS 2026 (Part 3): 2018 IS 2026 (Part 4):1977 Reaffirmed 2021 Part1: General Part 2: Temperature Rise Part 3: Insulation levels, dielectric tests, and external clearances in air Part 4: Terminal markings, tapings and connections

 

IS 2026 (Part 5): 2011 Reaffirmed 2016 IEC 60076-4:2002 IEC 60186:1987/AMD2:1995 IS 1180: Part 1: 2014 IS 11171 Rev1: 1985, Reaffirmed 2016 IEC 60076-4:2002 Part 5: Ability to withstand short circuit Part 4: Guide to the lightning impulse and switching impulse testing – Power transformers Voltage Transformers Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV – Specification Part 1 Mineral Oil Immersed (Fourth Revision) Specification for Dry Type Power Transformers Part 4: Guide to the lightning impulse and switching impulse testing – Power transformers

Instrument Transformer

Stagewise / Final Inspection

IS:2705 (Part 1) :1992 Reaffirmed 2002

IS : 2705 (part 2) : 1992 Reaffirmed 2002

IS : 2705 (part 3) : 1992 Reaffirmed 2002

 

Current Transformers -Specification Part 1: General Requirements Current Transformers -Specification Part 2: Measuring Current Transformers Current Transformers -Specification Part 3: Protective Current Transformers Current Transformers -Specification Part 4: Protective Current Transformers for special purpose applications

 

IEC: 61869-2:2012 IEC: 61869-3:2021

 

Instrument transformers – Part 2: Additional requirements for current transformers Instrument transformers – Part 3: Additional requirements for inductive voltage transformers.

 

AC Generators &

 
Stagewise / Final Inspection

IS 13364: Part 1: 1992 (Reaffirmed Year: 2018)

IS 13364: Part 2: 1992 (Reaffirmed Year: 2018) IEC 60034-1:2022 ISO 8528-1:2018 IEC 61020-1:1991  

AC Generators Driven by Reciprocating Internal Combustion Engine: Part 1 Rated Up To 20 KVA AC Generators Driven by Reciprocating Internal Combustion Engine Part 2 Rated Above 20 KVA and upto 1250 KVA Rotating Electrical Machines Part 1: Rating and Performance Push-button switches – Part 1: General requirements and measuring methods

 

Wires and Cable

Stagewise / Final Inspection IS 694 Rev4:2010, Reaffirmed 2015 IS 1554, Part1 (Rev3), Part2 (rev2): 1988, Reaffirmed 2015 Polyvinyl Chloride Insulated Unsheathed–And Sheathed Cables/ cords With Rigid And–Flexible Conductor for Rated Voltages–Up To and Including 1100 V PVC insulated (heavy duty) electric cables

IS 5831Rev1:1984, Reaffirmed 2016 IS 7098 (Part 1) Reaffirmed 2020

 

PVC insulation and sheath of electric cables Crosslinked polyethylene insulated PVC sheathed cables For working voltage upto and including 1 100 V

 

IS:7098 Part2 Rev2:2011, Reaffirmed 2016 IS:7098 Part3:1993, Reaffirmed 2014

 

for Working Voltages from 3.3 kV up to and Including 33 kV For working voltages from 66 kV upto and including 220 kV

 

ACSR Conductors

Stagewise / Final Inspection IS 8130 Rev2:2013 IS 10810:1984, Reaffirmed 2016 IS 13573 Rev1: 2011, Reaffirmed 2016 and ENA09-13 Issue2:2013 IS: 398 Part 1:1996 Reaffirmed 2001 Conductors for Insulated Electric Cables and Flexible Cords Methods of test for cables Cable jointing kits & Accessories for Extruded Power Cables ACSR Conductors for overhead transmission purposes Part 1: Aluminum stranded conductors

IS: 398 Part 2:1996 Reaffirmed 2002 IS: 398 Part 3:1976 (R1991) IS: 398 Part 4:1994 (R2014)

 

Part 2: Aluminum conductors galvanized steel rein-forced Part 3: Aluminum conductors, aluminized steel reinforced Part 4: Aluminum alloy stranded conductors (Aluminum magnesium silicon type)

 

IS: 398 Part 5:1992 (R2002) IEC 60888:2019 IEC 61089:1997

 

Part 5: Aluminum conductors – galvanized steel reinforced for extra high voltage (400 kV and above) Zinc-coated steel wires for stranded conductors Amendment 1 – Round wire concentric lay overhead electrical stranded conductors. OR any equivalent standards

 

HV Switchgear and Control Gear

Stagewise / Final Inspection

IS 12729:2004 IEC 62271-1:2017 AMD 2021

 

Common Specification for High Voltage Switchgear and control gear standards Common Specification for High Voltage Switchgear and control gear standards

 

LV switchgear and control gear

Stagewise / Final Inspection IS 13947 (Part1): 2004 IEC 60947-1: -2020  

Specification For Low-Voltage Switchgear and Control gear – Part 1: General Rules Specification For Low-Voltage Switchgear and Control gear – Part 1: General Rules OR any equivalent standards

 

Electrical switching circuits / boards Distribution Control panels

Stagewise / Final Inspection IS 8623:1993, Reaffirmed 2018 IS 13703:1993, Reaffirmed 2014 Low-Voltage Switchgear and Control gear assemblies Low-voltage fuses for voltages not exceeding 1 000 V AC or 1 500 V DC

IS 12021 Rev1: 2015 IS 9124:1979, Reaffirmed 2016 IEC 60255-27:2023

Control Transformers for Switchgear and Control gear for Voltages Not Exceeding 1000 V A.C. – Specification Guide for maintenance and field testing of electrical relays Measuring relays and protection equipment – Part 27: Product safety requirements

 

IS 7372 Rev1:1995, Reaffirmed 2017 IS 1651Rev4:2013 IS 1652 Rev4:2013 IS 6304 Rev2:1992, Reaffirmed 2017 IS 8320 Rev2:2000, Reaffirmed 2015 Lead-acid storage batteries for motor vehicles Stationary cells and batteries, lead-acid type (with tubular positive plates) Stationary Cells and Batteries, Lead-Acid Type with Plante Positive Plates Stationary batteries lead-acid type with pasted positive plates General Requirements and Methods of Tests for Lead-acid Storage Batteries  

Switches

Stagewise / Final Inspection

IS 9920:1985 Reaffirmed 2002

 

IS 8320Rev2:2000, Reaffirmed 2015

 

Batteries

Stagewise / Final Inspection

BIS IS 10918:1984 AMD 2 2013 IS 15549:2005 Reaffirmed 2015

 
Specification for vented type nickel cadmium batteries Stationary Valve Regulated Lead Acid Batteries  

IEC:60896-22-Edition 2004

Stationary lead-acid batteries

 

Insulators

Stagewise / Final Inspection IS 1445:1992 Reaffirmed 2018 

Specification for porcelain insulators for overhead power lines with a nominal voltage upto and including 1000V

 

Photovoltaic Inverters Energy Meters UPS Circuit Breakers Scada System Disconnector/Isolator LA/ Earthing System

Stagewise / Final Inspection Stagewise / Final Inspection Stagewise / Final Inspection Stagewise / Final Inspection Stagewise / Final Inspection Stagewise / Final Inspection Stagewise / Final Inspection IS 16169:2014, IEC 62116:2014 IS 12346:1999, IEC 60736 IS 16242 (part 1) 2014 IS:9135-1979 IS 15953: 2011 IS 9921 (Part-4) -1985 IS 3043: 1987  

Utility Photovoltaic inverters – Test procedure of islanding prevention measures Testing Equipment for AC electrical energy meters General and Safety Requirements for UPS Guide for testing of circuit breakers with respect of out of phase switching Supervisory Control And Data Acquisition(Scada) System for Power System applications Specification for Alternating current disconnectors (Isolators) and earthing switches for voltage above 1000 V. Code of practice for Earthing

 

Control Relay Panel

Stagewise / Final Inspection IS 12083: 1986 (Part-2)

Specification for Electrical relays

 

Solar PV Module (Range 30 Wp to 800 Wp) Solar PV Module (Range 30 Wp to 800 Wp) Solar PV Module (Range 30 Wp to 800 Wp)

Stagewise / Final Inspection Stagewise / Final Inspection Stagewise / Final Inspection IS 16077: 2013 (Part-1) IEC 61730 (Part1, Part-II) IEC 61215-1:2021 (Part- I,1.1,1.2,1.3, 1.4)  

Terrestrial photovoltaic (PV) modules – Design qualification and type approval – Part 1: Test requirements Photovoltaic (PV) module safety qualification Part 1: Requirements for construction Part 2: Requirements for testing Terrestrial photovoltaic (PV) modules – Design qualification and type approval Part 1: Test requirements Part 1-1: Special requirements for testing of crystalline silicon photovoltaic (PV) modules Part 1-2: Special requirements for testing of thin-film Cadmium Telluride (CdTe) based photovoltaic (PV) modules Part 1-3: Special requirements for testing of thin-film amorphous silicon based photovoltaic (PV) modules Part 1-4: Special requirements for testing of thin-film Cu(In,GA)(S,Se)2 based photovoltaic (PV) modules

 
The The following offices of Sunkonnect Advisory Services Private Limited are included under accreditation

Location

Address

Key activities performed

Gurugram (Main Office)

     

301-304, JMD Empire, Sector 62, Gurugram – 122102, Haryana, India      

Top Management functions, Quality Management System functions, administration & accounts, other key activities.

 

Inspection contract review, Inspection planning & execution, Inspection personnel authorization & assignment, Issue of inspection reports / certificates.

 Print 
 Close 