NABCB Accredited Inspection Bodies
QIC Protech Private Limited
Address Office No. 209, LSC Jaina Tower-III, A1 Janakpuri, New Delhi-110058, India
Contact Person Mr. Lavleen Tandon
Designation CEO
Tel +91 7830800691 , 8750551113
Fax N/A
Email ID tpi@qicprotech.com , info@qicprotech.com
Website www.qicprotech.com
Accreditation Cert. No.. IB 188
Valid From 24 Sep 2026
Valid Upto 23 Sep 2029
Accreditation Standard ISO/IEC 17020:2012
Type of Inspection Body Type A
Scopes of Accreditation
The following offices of QIC Protech Private Limited
IAF Scope /
Field of Inspection and
Specific Item(s)
Stage and Range of
Inspection(s)
Inspection Requirement(s)
Standards / Regulations / Methods / Procedures
Number identification Title
with          year          of
publication
 
IAF Scope 17
Basic metals and fabricated metal products
Tubes & Pipes
Steel Structure
Fasteners
Stage wise & Final
Inspection
Stage wise & Final
Inspection
Final Inspection
IS 1239:2004 (Part-1)
IS 1161: 2014
IS 800:2007
IS 1363 Part 2: 2023
IS 1363 Part 3: 2018
IS 1367 ( Part2) : 2002
Steel Tubes, Tubulars and other
wrought steels fittings-
specifications: part 1 Steel Tubes
Steel Tubes for Structural
Purposes-Specification
General Construction In Steel -
Code of Practice
Hexagon Head Bolts, Screws And
Nuts Of Product Grade C Part 2
Hexagon Head Screws (Size
Range M5 To M64)
Hexagon Head Bolts, Screws and
Nuts of Product Grade "C" Part 3
(Style 1) Hexagon Nuts ( Size
Range M 5 to M 64)
Technical Supply Conditions for
Threaded Steel Fasteners - Part 2
: Tolerances for Fasteners - Bolts,
Screws, Studs and Nuts - Product Grades A, B and C
Storage Tanks
Plate
Stage wise & Final
Inspection
Final Inspection
IS 1367 (Part 3): 2017
IS 3063:1994
IS 10987: 1992
IS 803: 1976
IS 2062 (Part 1): 2025
Technical Supply Conditions for
Threaded Steel Fasteners Part 3
Mechanical Properties of
Fasteners Made of Carbon Steel
and Bolts, Screws and Studs
Fasteners - Single coil rectangular
section spring lock washers -
Specification
Code of Practice for design,
fabrication, testing and installation,
of under-ground/above-ground
horizontal cylindrical steel storage
tanks for petroleum products
Code of practice for design,
fabrication and erection of vertical
mild steel cylindrical welded oil
storage tanks
Structural Steel - Part 1 Hot Rolled
Medium and High Tensile Steel
  Client Requirements in the form of QAP mentioning required specification and scope mentioned in this scope. However, the applicable National & International Codes and Standards shall be among those which are either referred in the scope statement or shall be equivalent to the standards described above for the relevant scope category.

Location

Address

Key activities performed

Delhi (Main Office)

   

Office No. 209, LSC Jaina Tower-III, A1 Janakpuri, New Delhi-110058, India

Top Management functions, Quality Management System functions, administration & accounts, other key activities.

 

Inspection contract review, Inspection planning & execution, Inspection personnel authorization & assignment, Issue of inspection reports / certificates.